Weak alkaline electrolysis water is activated and alkaline by electricity, and does not add any alkaline substance in its process. Alkaline electrolyzed water belongs to alkaline food, which can change our acidic constitution. Acid water contains harmful substances such as sulfate and perchloric acid, but it has bacteriostatic and disinfectant effects.
Compare

Alkaline Electrolyzed Water Ionizer is activated and alkaline by electricity, and does not add any alkaline substance in its process. Alkaline electrolyzed water belongs to alkaline food, which can change our acidic constitution. Ordinary water generally pH sex is neutral (pH=7), according to the principle of electrical decomposition, the electrolysis water generator separates water into oxidizing water and reducing water, which are acid water (pH < 7) and alkaline water (pH > 7). At the same time, due to the attraction of positive and negative charges, alkaline water contains a lot of beneficial elements, such as calcium, magnesium, potassium, sodium, etc., and is ion state, which is more conducive to the absorption of the human body. Acid water contains harmful substances such as sulfate and perchloric acid, but it has bacteriostatic and disinfectant effects.

The process flow

1?system flow

raw water tank? raw water pump?Security filter ?Electrolytic water generator ?The weak base tank

Schematic diagram of water and electricity road connection.

(1) design description

The state’s pH requirement for drinking water is between 6.5~8.5, so the effluent pH index of the designed water electrolysis equipment is between 7 and 9.5 (users can adjust themselves). The electrolysis water generation system consists of electrolyzer, electric control, instrument, cabinet and so on.

(2) equipment description

Lambda security filter

Filtration of impurities above 0.22/0.45 microns in water. Prevent other impurities in the intermediate water tank or pipe, damage the electrolysis water generator.

Lambda electrolysis water generator WATER IONIZER

Fang Xin brand third generation electrolysis water generator is the lowest electrolytic water generator in the world.

The use of acid electrolysis water

In the process of water electrolysis, weak acidic electrolysis water can also be generated when weak alkaline electrolysis water is generated. Weakly acidic electrolyzed water can be used as plant equipment, ground, air and staff for disinfection and sterilization.

Weak alkalinity is only one of the indexes of alkaline electrolysis water. Its complete target is:

(1) purification. It does not contain any toxic, harmful or odorous substances to the human body.

(2) alkalinity. The pH value is weak alkalinity (7 ~ 9).

(3) ionic state. The contents and proportions of minerals and trace elements required by human body are moderate and exist in ionic form.

(4) negative potential. Free radicals can be removed in the body.

(5) small molecular mass. The water molecular mass is small (170 nuclear magnetic resonance half peak width is lower than 90Hz) dissolving force, seepage force, replacing Xie Liqiang;

(6) hydrogen rich.

Design principles and scope

1) design principles

The source of water entering the water treatment system is water after reverse osmosis, and the water quality design is calculated according to the water quality indicators provided by users.

The whole water treatment facilities have greater adaptability and should be acute to meet the changes of water quality and water volume.

The technology is reliable, mature, stable in operation, low in operation cost, small in management and maintenance, and high in automation.

All low pressure pipes in the system are UPVC pipes.

2) the scope of engineering design

Equipment limit: 2 meters from the total intake to 2 meters away from the terminal outlet.

Control limits: raw water inlet to terminal water quality on-line detection;

Electricity, water and so on: from the buyer to the relevant equipment department;

Drainage: from the buyer to the equipment indoor drainage.

Water storage facilities: there are water storage facilities such as raw water tank, intermediate water tank and finished water tank.

3) site construction conditions

Low voltage power supply: AC380V + 5%, 50Hz, 3P+1N+1PE;

Low voltage control and lighting power supply: AC220V + 5%, 50Hz, 1P+1N+1PE;

Water supply flow rate: more than 12 T/H.

The pH value of the original water should not be less than 6.8.

The conductivity of the original water is 80~240 mu s/cm.

4) equipment specification index

Power demand for equipment: AC380V

Water capacity of equipment: electrolysis weak alkali water 6T/H, pH=7.0 ~ 9.5